Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
2.
Chemosphere ; 254: 126831, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32957272

RESUMO

The problem of bacterial antibiotic resistance has attracted considerable research attention, and the effects of water treatment on antibiotic resistant bacteria (ARB) and antibiotic resistance genes (ARGs) are being increasingly investigated. As an indispensable part of the water treatment process, disinfection plays an important role in controlling antibiotic resistance. At present, there were many studies on the effects of conventional and new sterilization methods on ARB and ARGs. However, there is a lack of literature relating to the limitations of conventional methods and analysis of new techniques. Therefore, this review focuses on analyzing the deficiencies of conventional disinfection and the development of new methods for antibiotic resistance control to guide future research. Firstly, we analyzed the effects and drawbacks of conventional disinfection methods, such as chlorine (Cl), ultraviolet (UV) and ozone on antibiotic resistance control. Secondly, we discuss the research progress and shortcomings of new sterilization methods in antibiotic resistance. Finally, we propose suggestions for future research directions. There is an urgent need for new effective and low-cost sterilization methods. Disinfection via UV and chlorine in combination, UV/chlorine showed greater potential for controlling ARGs.


Assuntos
Desinfecção/métodos , Esterilização/métodos , Purificação da Água/métodos , Cloro/farmacologia , Desinfecção/tendências , Farmacorresistência Bacteriana/genética , Esterilização/tendências , Raios Ultravioleta
3.
AORN J ; 110(4): 415-425, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31560430

RESUMO

Establishing and maintaining a sterile field to help prevent surgical site infections requires specific knowledge and skills and is among the most important responsibilities of the perioperative RN. Perioperative RNs should remain vigilant in monitoring the sterile field, communicate when a break in sterile technique occurs, and collaborate with other surgical team members to correct the break in technique. The AORN "Guideline for sterile technique" provides guidance to perioperative personnel on the principles and processes of sterile technique. This article elaborates on key takeaways from the guideline, including using sterile technique when donning sterile gowns and gloves, delivering sterile items to the sterile field, using drapes to establish a sterile field, and maintaining the sterile field. Perioperative RNs should review the complete guideline for additional information and for guidance when writing and updating policies and procedures.


Assuntos
Guias como Assunto , Enfermagem Perioperatória/métodos , Esterilização/métodos , Anti-Infecciosos Locais/normas , Anti-Infecciosos Locais/uso terapêutico , Educação Continuada em Enfermagem/métodos , Contaminação de Equipamentos/prevenção & controle , Humanos , Enfermagem Perioperatória/normas , Enfermagem Perioperatória/estatística & dados numéricos , Esterilização/tendências , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/prevenção & controle
4.
Am J Infect Control ; 47S: A62-A66, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31146853

RESUMO

Millions of gastrointestinal endoscopes are performed each year in the United States. Gastrointestinal endoscopes become highly contaminated during use (ie, internal channels contain 7-10-log10 enteric microorganisms). Currently, endoscopes (eg, bronchoscopes and gastrointestinal endoscopes) are classified as semicritical items because they contact intact mucous membranes and most commonly undergo cleaning followed by high-level disinfection, which may result in as little as a 6-log10 reduction of microorganisms. Therefore, and not surprisingly, in recent years there have been multiple reports that have documented that endoscopes, especially duodenoscopes, frequently remain contaminated with bacterial pathogens after proper cleaning and disinfection. Multiple outbreaks of multidrug-resistant organisms from contaminated duodenoscopes have resulted in substantial death and morbidity. Because duodenoscopes commonly contact nonintact mucous membranes and sterile tissue, such endoscopes should be considered critical items. We propose that to ensure patient safety, we follow the Spaulding scheme and move from high-level disinfection to sterilization of reusable endoscopes or use an alternative diagnostic/therapeutic method (eg, disposable sterile endoscopes).


Assuntos
Infecção Hospitalar/prevenção & controle , Transmissão de Doença Infecciosa/prevenção & controle , Endoscópios/microbiologia , Endoscopia Gastrointestinal/efeitos adversos , Segurança do Paciente , Esterilização/métodos , Esterilização/tendências , Humanos , Estados Unidos
5.
BJS Open ; 3(3): 282-287, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31183443

RESUMO

Background: The efficacy of widely used povidone-iodine applicators for skin sterilization in abdominal surgery is unclear. The aim of this trial was to evaluate whether sterilization with a povidone-iodine applicator was not inferior to a conventional sterilization method. Methods: Patients undergoing elective abdominal surgery were assigned randomly to receive single sterilization with the applicator or conventional sterilization. The primary endpoint was wound infection rate. Secondary endpoints were rate of organ/space surgical-site infection (SSI), adverse effects of povidone-iodine, amount of povidone-iodine used and total cost of sterilization. Results: Of 498 patients eligible for the study between April 2015 and September 2017, 240 were assigned and analysed in the applicator group and 246 in the conventional group. Wound infection was detected in 16 patients (6·7 per cent) in the applicator group and 16 (6·5 per cent) in the conventional group (absolute difference 0·0016 (90 per cent c.i. -0·037 to 0·040) per cent; P = 0·014 for non-inferiority). There was no difference between the groups in the organ/space SSI rate (11 patients (4·6 per cent) in the applicator group and 16 (6·5 per cent) in the conventional group. Both the amount of povidone-iodine used and the total cost of sterilization were higher in the conventional group than in the applicator group (median 76·7 versus 25 ml respectively, P < 0·001; median €7·0 versus €6·4, P < 0·001). Skin irritation was detected in three patients in the conventional group. Conclusion: In abdominal surgery, this povidone-iodine applicator was not inferior to conventional sterilization in terms of the wound infection rate, and it is cheaper. Registration number: UMIN000018231 (http://www.umin.ac.jp/ctr/).


Assuntos
Abdome/cirurgia , Anti-Infecciosos Locais/efeitos adversos , Povidona-Iodo/efeitos adversos , Pele/efeitos dos fármacos , Esterilização/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Eletivos/tendências , Feminino , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Pele/patologia , Esterilização/economia , Esterilização/tendências , Infecção da Ferida Cirúrgica/epidemiologia
6.
Rev. pesqui. cuid. fundam. (Online) ; 10(3, n. esp): 49-52, jun. 2018.
Artigo em Português | LILACS, BDENF - Enfermagem | ID: biblio-905333

RESUMO

A implantação da CME centralizada na Atenção Primária mostrou-se uma alternativa para adequação do serviço de esterilização a legislação vigente. Com base nos resultados do presente estudo, assumimos a proposição de indicação da centralização do serviço de esterilização para todas as unidades de saúde que necessitem de reprocessamento de artigos enquanto uma medida de qualidade e segurança bem como investimento nas questões que precisam de avanço e implementação nas unidades básicas de saúde


Assuntos
Humanos , Feminino , Esterilização/economia , Esterilização/instrumentação , Esterilização/tendências , Atenção Primária à Saúde , Gestão da Qualidade Total
10.
Am J Infect Control ; 44(5 Suppl): e23-7, 2016 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-27131131

RESUMO

A review of regulatory clearances for selected new sterilization and disinfection products for the period January 2012-June 2015 indicates continued leverage of established technologies for steam and low-temperature sterilization, and high-level disinfection. New products in these areas were typically modified and improved versions of existing products, with the exception of a new combination hydrogen peroxide/ozone sterilizer. Development of new low-temperature sterilization technologies to address continued evolution of complex medical devices is expected to continue.


Assuntos
Infecção Hospitalar/prevenção & controle , Esterilização/métodos , Esterilização/tendências , Humanos
11.
Fertil Steril ; 106(3): 704-709.e1, 2016 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-27172400

RESUMO

OBJECTIVE: To describe trends in age-specific incidence rates of female sterilization (FS) procedures in Western Australia and to evaluate the effects of the introduction of government-subsidized contraceptive methods and the implementation of the Australian government's baby bonus policy on FS rates. DESIGN: Population-based retrospective descriptive study. SETTING: Not applicable. PATIENT(S): All women ages 15-49 undergoing an FS procedure during the period January 1, 1990, to December 31, 2008 (n = 47,360 procedures). INTERVENTION(S): Records from statutory statewide data collections of hospitals separations and births were extracted and linked. MAIN OUTCOME MEASURE(S): Trends in FS procedures and the influence on these trends of the introduction of government policies: subsidization of long-acting reversible contraceptives (Implanon and Mirena) and the Australian baby bonus initiative. RESULT(S): The annual incidence rate of FS procedures declined from 756.9 per 100,000 women in 1990 to 155.2 per 100,000 women in 2008. Compared with the period 1990-1994, women ages 30-39 years were 47% less likely (rate ratio [RR] = 0.53; 95% confidence interval [CI], 0.39-0.72) to undergo sterilization during the period 2005-2008. Adjusting for overall trend, there were significant decreases in FS rates after government subsidization of Implanon (RR = 0.89; 95% CI, 0.82-0.97) and Mirena (RR = 0.81; 95% CI, 0.73-0.91) and the introduction of the baby bonus (RR = 0.70; 95% CI, 0.61-0.81). CONCLUSION(S): Rates of female sterilization procedures in Western Australia have declined substantially across all age groups in the last two decades. Women's decisions to undergo sterilization procedures may be influenced by government interventions that increase access to long-term reversible contraceptives or encourage childbirth.


Assuntos
Regulamentação Governamental , Política de Saúde/tendências , Hospitais/tendências , Padrões de Prática Médica/tendências , Esterilização/tendências , Saúde da Mulher/tendências , Adolescente , Adulto , Fatores Etários , Compensação e Reparação , Anticoncepcionais Femininos/uso terapêutico , Feminino , Política de Saúde/economia , Humanos , Formulação de Políticas , Padrões de Prática Médica/economia , Padrões de Prática Médica/legislação & jurisprudência , Gravidez , Estudos Retrospectivos , Esterilização/economia , Esterilização/legislação & jurisprudência , Esterilização/estatística & dados numéricos , Fatores de Tempo , Austrália Ocidental , Saúde da Mulher/economia , Saúde da Mulher/legislação & jurisprudência , Adulto Jovem
12.
Med. oral patol. oral cir. bucal (Internet) ; 20(4): e413-e418, jul. 2015. ilus
Artigo em Inglês | IBECS | ID: ibc-138967

RESUMO

BACKGROUND: The aim of the study was to focus the awareness of complications of oral piercing among a group of adolescents and young Italian adults with intraoral piercings. MATERIAL AND METHODS: A total of 225 teenagers were asked to complete a questionnaire on the awareness of complications of oral piercing. An additional questionnaire was administered in case of oral piercing worn, based on site piercing, knowledge about piercer license, oral and systemic risks due to oral piercing, disinfection and sterilization of the material pierced, information by the piercer about piercing hygiene maintenance and post-piercing dentist check-up. After questionnaire all partecipants received a brochure with some information about risks and maintenance mode of piercing. RESULTS: Data revealed that more than 50% of teens surveyed was found to wear a piercing. Only 25.3% was aware of the risk of HCV cross-infection and only 17.3% reported of knowledge about risk of endocarditis. Only 17% checked the piercer license and only 18% sterilization and disinfection of the materials used. 53.7% did not received explanations about the risks associated with piercing. With regard to the maintenance mode of the piercing, it has been suggested to brush the piercing bar in 17% of cases. The post piercing specialist visits have been suggested only in 7% of cases. CONCLUSIONS: The general lack of awareness of complications and maintenance mode related to oral piercing needs to be addressed by some education programs performed at school and by dentists


No disponible


Assuntos
Adolescente , Feminino , Humanos , Masculino , Piercing Corporal/efeitos adversos , Piercing Corporal , Piercing Corporal/tendências , Fatores de Risco , Saúde Bucal/educação , Saúde Bucal/normas , Saúde Bucal/tendências , Desinfecção/tendências , Esterilização/tendências , Doenças da Boca/complicações , Doenças da Boca/epidemiologia , Doenças da Boca/prevenção & controle , Endocardite/complicações , Endocardite/epidemiologia
13.
J Med Pract Manage ; 30(6 Spec No): 48-50, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26062318

RESUMO

Operative sterility is a critical factor with regard to infection in the postoperative period. In recent years, techniques and devices have been developed to reduce the potential for exposure to pathogens. This brief review details the SteriCup, a unique product that has the potential to reduce the risk of healthcare-acquired infections. The SteriCup provides a designated sterile area to store suction catheters and removed endotracheal tubes and allows for their simple and safe disposal. Devices such as the SteriCup have the potential to improve operating room systems and minimize potential for operative infection.


Assuntos
Infecção Hospitalar/prevenção & controle , Assistência Perioperatória/instrumentação , Assistência Perioperatória/tendências , Esterilização/instrumentação , Esterilização/tendências , Infecção da Ferida Cirúrgica/prevenção & controle , Desenho de Equipamento , Equipamentos e Provisões , Humanos , Salas Cirúrgicas
15.
Acta cir. bras ; 29(4): 218-223, abr. 2014. graf
Artigo em Inglês | LILACS | ID: lil-706960

RESUMO

To evaluate the female sterilization by occlusion of the ovarian blood flow, using the rat as experimental model. Fifty-five females rats were divided into four groups: I (n=10), bilateral ovariectomy, euthanized at 60 or 90 days; II (n=5), opening the abdominal cavity, euthanized at 90 days; III (n=20), bilateral occlusion of the ovarian blood supply using titanium clips, euthanized at 60 or 90 days; and IV (n=20), bilateral occlusion of the ovarian blood supply using nylon thread, euthanized at 60 or 90 days. The estrous cycle was monitored by vaginal cytology. After euthanasia, the reproductive tissues were evaluated histologically. RESULTS: Ovarian atresia was identified macroscopically at 60 days after surgery in the rats in groups III and IV; however, most of the rats in group III maintained cyclicity. Histology of the tissues from group IV revealed that the ovarian tissue was replaced by dense fibrous connective tissue that was slightly vascularized and that intact follicles were absent by 90 days. OOvarian blood vessels occluded caused ischemia, leading to progressive tissue necrosis, and bilateral occlusion using a nylon ligature is a viable method for surgical sterilization.


Assuntos
Animais , Ratos , Castração/veterinária , Esterilização/tendências , Ovário/anatomia & histologia , Vasos Sanguíneos/anatomia & histologia , Ovariectomia/veterinária , Ratos/classificação
20.
Khirurgiia (Mosk) ; (6): 43-7, 2011.
Artigo em Russo | MEDLINE | ID: mdl-21716218

RESUMO

The comparative characteristic of the accepted methods of low-temperature sterilization of medical equipment is given. Special attention is devoted to the surgical infection prophylaxis. The efficacy, expediency and safety of gas sterilization with ethilenoxide is proved. Plasmic methods of sterilization is recommended for use together with other methods of low-temperature sterilization.


Assuntos
Temperatura Baixa , Infecção Hospitalar/prevenção & controle , Desinfetantes/farmacologia , Contaminação de Equipamentos/prevenção & controle , Esterilização/métodos , Antibacterianos/farmacologia , Bactérias/efeitos dos fármacos , Infecção Hospitalar/microbiologia , Óxido de Etileno/farmacologia , Estudos de Avaliação como Assunto , Formaldeído/farmacologia , Humanos , Peróxido de Hidrogênio/farmacologia , Ácido Peracético/farmacologia , Esterilização/tendências , Equipamentos Cirúrgicos/microbiologia , Instrumentos Cirúrgicos/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...